PPGL Trade References 2005 - 2010
|
Year |
Equipment |
Rating kW |
Volts |
Speed |
Freq |
Protection |
Cooling |
Destination |
|
2005 |
WI & Booster Pump |
4900 |
11000 |
2 |
60 |
EEx p |
CACW |
UK Offshore |
|
2005 |
Recip Compressor |
1350 |
6600 |
18 |
50 |
EEx p |
CACA |
India |
|
2005 |
Mill |
2760 |
10000-11000 |
12 |
50 |
Safe |
EVDP |
Australia |
|
2005 |
CW Pump |
4255 |
11000 |
6 |
50 |
Safe |
CACA |
UK |
|
2005 |
Gas Inj Compressor |
14800 |
11000 |
4 |
50 |
Ex p |
CACA |
Oman |
|
2005 |
WI Pump |
5100 |
10000 |
4 |
50 |
Ex nA |
CACA |
Russia |
|
2006 |
Slurry Pump |
375/280 |
3300 |
6/8 |
50 |
Safe |
EVDP |
Australia |
|
2006 |
MP Compressor |
7350 |
11000 |
2 |
50 |
Ex p |
CACA |
Nigeria |
|
2006 |
Flash Gas Compressor |
1900 |
13800 |
4 |
60 |
Ex p |
CACW |
UK Offshore |
|
2006 |
FD Fan |
1209/858 |
11000 |
12/14 |
50 |
Safe |
CACW |
UK |
|
2006 |
CW Pump |
2835 |
11000 |
6 |
50 |
Safe |
CACW |
UK |
|
2007 |
Recip Compressor |
200 |
3300 |
8 |
50 |
Ex nA |
CACA |
Abu Dhabi UAE |
|
2007 |
PM Generator |
90 kVA |
200 |
2 |
50 |
Safe |
Air Cooled |
UK |
|
2007 |
2 Pole Generator |
27500 kVA |
11500/13800 |
2 |
50/60 |
Safe |
Filter Vent (Air) |
USA |
|
2007 |
Pump |
720 |
3300 |
2 |
50 |
Ex nA |
CACA |
Nigeria |
|
2007 |
Comp/Expander |
3750 |
6000 |
4 |
50 |
Ex nA |
NEMA II (air) |
Hungary |
|
2007 |
TurboCompressor |
1210 |
11000 |
2 |
50 |
Ex nA |
CACA |
UK |
|
2007 |
Boiler Feed Pump |
625 |
3300 |
2 |
50 |
Safe |
CACA |
Sudan |
|
2008 |
Offgas Compressor |
1900 |
11000 |
4 |
60 |
Ex p |
CACW |
UK |
|
2008 |
Vertical Pump |
4476 |
4160 |
36 |
60 |
Safe |
NEMA II (air) |
USA |
|
2008 |
Recip Compressor |
1680 |
4000 |
16 |
60 |
Ex nA |
CACW |
Korea |
|
2008 |
Spare Rotor |
|
|
|
|
|
|
UK |
|
2008 |
Recip Compressor |
7500/3000 |
4160 |
20/40 |
60 |
Safe |
NEMA II (air) |
USA |
|
2008 |
WI Pump |
6800 |
13800 |
2 |
60 |
Ex nA |
CACW |
UK Offshore |
|
2008 |
FD Fan |
1209/858 |
11000 |
12/14 |
50 |
Safe |
|
UK |
|
2008 |
Spare Rotor |
|
|
|
|
|
|
Egypt |
|
2008 |
Vertical Pump |
2610 |
4000 |
18 |
60 |
Safe |
NEMA I (air) |
USA |
|
2009 |
CW Pump Drive |
2835 |
11000 |
6 |
50 |
Safe |
CACW |
UK |
|
2009 |
Spare Stator |
2400 |
6000 |
4 |
60 |
Safe |
|
Brasil |
|
2009 |
Spare Rotor |
|
|
|
|
|
|
UK |
|
2009 |
Frequency Changer |
12000 |
11000 |
10/12 |
50/60 |
Safe |
EVDP |
UK |
|
2009 |
Spare Stator/Rotor |
|
|
|
|
|
|
France |
|
2009 |
CW Pump Drive |
2835 |
11000 |
6 |
50 |
Safe |
CACW |
UK |
|
2009 |
Compressor/Expander |
8500 |
11000 |
4 |
50 |
ExN |
CACW |
UK |
|
2009 |
Turbo Compressor |
2775 |
11000 |
2 |
50 |
ExN |
CACA |
UK |
|
2009 |
Compressor |
13100 |
13800 |
4 |
60 |
Exp |
CACW |
UK |
|
2009 |
Gas Compressor |
7300 |
11000 |
4 |
50 |
ExN |
CACW |
UK |
|
2010 |
Compressor |
2380 |
11000 |
2 |
60 |
Exp |
CACW |
UK |
|
2010 |
FD Fan Drive |
1050 |
3300 |
6 |
50 |
Safe |
CACA |
Nigeria |
|
2010 |
BFP Drive |
1600 |
3300 |
2 |
50 |
Safe |
CACA |
Nigeria |
|
2010 |
CW Pump Drive |
2835 |
11000 |
6 |
50 |
Safe |
CACW |
UK |
|
2010 |
Pony Motor |
7085 |
3300 |
10 |
50 |
Safe |
EVDP |
UK |
|
2010 |
Pony Motor |
7085 |
3300 |
10 |
50 |
Safe |
EVDP |
UK |
|
2010 |
Compressor |
13100 |
13800 |
4 |
60 |
Exp |
CACW |
UK |
Back to Trade References
|